PRODUCT

Rubber Insulated Welding Electric Cable
0.0 Yuan 0.0 Yuan
Detail
[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[产品参数, 参数]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]

Packaging & Delivery

Packaging Detail:

100M/Coil, 500M/Coil, 1000M/Reel;

Delivery Detail:

10-20working days acc. to the order qty;

Specifications

Welding Cable 
-High elasticity, aging resistance & oil resistance 
-Sample for free 
-7-10days delivery
6AWG 4 3 2 1 1/0 2/0 3/0 4/0AWG  Rubber Insulated Welding Electric Cable

I. Specifications

1.Conductor: Tinned Copper, Copper or CCA Conductor
2.Rubber Insulated Welding Cable 16mm, 25mm, 35mm, 50mm, 70mm, 95mm, 120mm, 150mm, 185mm, 240mm; 6AWG, 4AWG, 2AWG, 1AWG, 1/0, 2/0, 3/0, 4/0

 

Welding Cable H01N2-E IEC60245

Copper rubber welding cable, PVC welding cable, CCA welding cable,

 

 

Application

This kind of cable is suitable for use in secondary earth welder as secondary earth wire for conductor earth colatages up to 200V AC and impulse coltage pead 400V PC, or for connecting electrode holder.

 

Operating Characteristcs

Continuous operating temperatrue: ≤60degree

 

Standard & description

TYPE

standard

245 IEC 81(YH)

GB5013.6-1997

TYPE

Description

245 IEC 81(YH)

Welding Cable, sheathed with natural rubber

245 IEC 81(YH)

Order

Item

Property

1

Conductor DC Resistance (Ω/km)

Reference the table followed

2

Power frequency AC voltange test

Immersed in water at room temperatrues for 1hour finished cable withstands 1000V AC.50Hz.For 5 minute without breakdown

 

Specification

Nominal cross sectional area 
(mm2)

The max. Diameter of conductor wire 
(mm)

DC conductor reslstance at 20degree?(Ω/km)

Reference diameter 
of conductor 
(mm)

Insulaton nominal 
thickness 
(mm)

Overall diameter (mm)

Reference weight 
(kg/km)

Untinned

Tinned

Min.

Max.

16

0.21

1.16

1.19

6.03

2.0

9.2

11.5

224

25

0.21

0.758

0.78

7.14

2.0

10.5

13.0

317

35

0.21

0.536

0.552

8.50

2.0

11.5

14.5

422

50

0.21

0.379

0.39

10.12

2.2

13.5

17.0

586

70

0.21

0.268

0.276

11.69

2.4

15.5

19.5

796

95

0.21

0.198

0.204

14.03

2.6

18.0

22.0

1060

6AWG 4 3 2 1 1/0 2/0 3/0 4/0AWG Rubber Insulated Welding Electric Cable

II. Cable detailed information:

1. Cable working temperature should not exceed 65 degree

2. Cable have a certain extent of temperature resistance and oild resistance, fit to work outdoor and smeary 
enviroment

3. Reach standard GB/T18380.1-2001 vertical flame test

4. When cable working in temperature 20 degree, the insulation between Conductors above 50M .KM

 

Applicable scope: Rated voltage 300/500V or below, Applied in electric Appliance, elctromotive tools and equipment.

扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加

底部黑字

Time of issue:2019-10-12 00:00:00

Copyright◎Wanxingda Industrial co.,ltd All right reserved    Head Office: Wanxingda Industrial co.,ltd   Factory:Xingda Cable Co.,Ltd     POWERED BY Foshan Tel:+86-757-85223960(6 lines)   Fax:+86-757-85223915      粤ICP备14081090号

 

1